Auto Chemistry Analyzer ME-500(DIAMOND)
Features:
90 Sample positions.
120 Reaction cuvettes (reusable).
90 Refrigerated reagent positions (R1:45 & R2:45).
Auto 7-step washing system.
550 tests per hour with STAT function.
One sample probe, two reagent probes, Anti-collision function.
Liquid level detection function, real-time display reagent volume.
OverallPerformance | Model | ME-500(DIAMOND) |
Type | Random, Discrete, fully automatic | |
Test Speed | 550Tests/Hour | |
Analysis Method | End-point, Fixed-time, Rate, Two-points, Turbidimetry | |
Certificates | CE, FDA, ISO9001, ISO14001, ISO13485 | |
Sample unit | Sample Settings | 90 sample positions, including calibration, quality control and emergency |
Sample Volume | 2ul ~70ul (0.1ul stepping) | |
Sample Probe | Liquid level detection function | |
Probe Washing | Automatically wash interior and exterior | |
Analysis Items | Analyzing maximally 45 items at the same time | |
Reagent unit | Reagent Position | R1: 45, R2: 45, total 90 refrigerated reagent positions |
Reagent Volume | 20~350μl (1μl stepping) | |
Temperature Control | 2°C~8°C cooling for 24 hours | |
Reagent Probe | Liquid level sensor function | |
Probe cleaning | Automatically wash interior and exterior | |
Reaction unit | Temperature | 37°C±0.1°C, real-time monitor |
Cuvettes | 120 reusable reaction cuvettes (optical path length 6mm) | |
Mixer Probe | After adding reagent and sample, mix immediately | |
Washing | Automatically cuvettes washing | |
System adjustment | System can record the blank value and get more,accurate results by deducting blank base value of each cuvette | |
Optical System | Light Source | 12V/30W halogen-tungsten lamp, 2000 hours lifetime |
Receiver | 8 precision photo receivers | |
Wavelength Range | 340, 405, 450, 510, 546, 578, 630, 700mm | |
Linear Range | 0.000~3.000Abs | |
Calibration and QC | Calibration | One-point, two-point, multi-point, factor, logit-4P, logit-5P, spline |
Quality Control | Inserting quality control at random | |
Software | STAT Function | Emergency samples can be placed in the sample tray at any time |
Computer System | Windows 7/8/10, LIS system available | |
Data Processing | Reaction curve and data display function | |
Others | Power Supply | AC110/220V±10%, 60/50Hz |
Consumption | 750w | |
Package Size(W*D*H) | 1348*928*1399mm(Machine) 678*624*548mm(Accessories) | |
Gross weight | 360kg |
Reaction tray
37°C±0.1°C, real-time monitor.
Reagent tray
2°C~8°C cooling for 24 hours.
Stirring needle
Teflon coating to avoid cross contamination
Sample needle
Liquid level sensor function. Anti-collision function. Reagent volume real-time detection.
Software
User-friendly software
Washing Probe
Independent 7-step washing system.