Medical Multifunctional Blood Donation Chair (ME-YD-211)

Share
documents & resoures

Medical Multifunctional Blood Donation Chair (ME-YD-211)


Description of Multifunctional Blood Donation Chair (ME-YD-211):

Whole chair with steel frame provide strong bearing capability, safe working load upto 240kg.

High density (45D) polyurethane foam for mattress with moderate elasticity anddurability provides additional comfort for patients having to sit for long periods.Soft upholstery makes of breathable PVC material, which is waterproof, fireretardant, anti-corrosion, easily clean & disinfection.The PVC leather is resistant todisinfectants, blood and urine too.

Four upholstery colors to choose from. Warm & light colors of upholstery contributeto patient's mental well-being.

The hand control and two Denmark Linak motors allow for quick positioning for anysituations, including trendelenburg (or shock position) with the push of one button.Mute medical castors of p 100mm with separate brake.

The detachable headrest pillow can be adjusted according to the height of eachpatient.

Several OPTIONAL accessories(for extra charge):Battery,LED reading lamp, paper rollholder, Over-bed Table, folding table.

Advangtages Of The Dialysis Chair(ME-YD-211)

1.Saving Space
Overall chair dimension: L 1980mm * W 600mm * H 550mm. Smaller overall chairdimension to save up to 40% of floor space.(Saving about 40% space than a hospital bed.)

2.Multi-position adjustment
Multiple independent adjustment possibilities by 2 Denmark Linak motors and onespring gas offer maximum patient comfort and reduction in staff work load.

The Environmental Of Installing Electric Dialysis Chair ME-YD-211

1. Water supply temperature
The 1kW heater can only heat 500ml/min water 28 ° C. For low -power heater, the water supply temperature and dialysis fluid flow should be considered. The dialysis machine only has heating and heating function, and cooling can only rely on naturally dissipating heat. Therefore, the temperature in the water is too high, and the machine cannot operate normally.

2.Water supply
Single water supply flow 500ml/min.
The water supply of most models is intermittent, so the water supply flow is greater than the actual dialysis liquid flow.
When some models are cleaned and disinfected, the actual traffic will be higher than the treatment flow (500ml/min).
Part of the treatment requirements in the treatment requirement using high dialysis liquid flow treatment is an example, which has little effect on the total water supply requirements.

Repair and maintenance

1. Regular inspection
To ensure safe use, regular inspections and mainte                  nance must be performed.

2. Cleaning and disinfection of chairs
When cleaning, first wipe the neutrally detergent diluted with water, and then wipe it with a dry cloth. It is forbidden to wipe the use of volatile solvents (scarcity, volatile oil, gasoline, etc.). Otherwise, there is a danger of discoloration and deterioration. When using disinfectant, the following drugs must be diluted to the specified concentration before use. 0.05 ~ 0.2%chloroblaxane ammonium, 0.05 ~ 0.2%chloride cylindrite ammonium, 0.05 ~ 0.2%washing Bibita.

(Attention: This dialysis chair is not suitable for disinfection with ozone sterilizers and high -voltage steam.)


Electric Dialysis Chair ME-YD-211
Complete sizeL1980 x W600 x H550 mm
G.W,/N.W.78/63KG/UNIT
20'GP45Units
40'HQ128Units
Packaging SizeL113cm*W72cm*H61cm
LeatherPVC Leather



Medical Multifunctional Blood Donation Chair (ME-YD-211)

Medical Multifunctional Blood Donation Chair (ME-YD-211)Medical Multifunctional Blood Donation Chair (ME-YD-211)