12.1" Color TFT Touch Screen Patient Monitor ME9000C

Share
documents & resoures

12.1" Color TFT Touch Screen  Patient Monitor ME9000C


12.1" color TFT touch screen

Windows style, Multi-channel display

Big font interface

ST and arrhythmia analysis

Drug dose calculation and titration table

OxyCRG dynamic view display

Respiration monitoring with apnea alarms

Alarm review, arrhythmia review

Patient info. Input

Anti-defibrillation design

NIBP over pressure protection

Plug-in rechargeable battery, AC/DC available. 

Supporting wire or wireless network.


Adopting Aiah(TM) ECG technology, anti-interference, be able to collect the weak ECG signal away from interference.

Adopting Surepeb(TM) NIBP technology, accurate measurement to high blood pressure patient and low blood pressure patient.


SP02


Nellcor(TM)  OxiMax(TM) is the world leading SpO2 technology

Nellcor(TM)  OxiMax(TM) delivers excellent performance,

even in the difficult monitoring conditions of low perfusion and signal interference, including patient motion.


ETCO2

Collaborate with Respironics, Plug and Play EtCO2 monitoring.

CAPNOSTAT mainstream sensor for optimal performance in monitoring intubated patient. Small, durable and lightweight mainstream sensor provides accurate

and reliable monitoring for all intubated patients from neonates to adults. Loflo sidestream sensor for monitoting non-intubated patient.

Flexible, compact CO2 sensor provides consistent and reliable monitoring of adult, pediatric and neonatal patients.


Multi Mounting Solutions

ECG


Lead Mode                          5 Leads (R, L, F, N, C or RA, LA, LL, RL,V) 

Lead selection                     I, II, III, avR, avL, avF, V

Wave form                          2 ch

Lead mode                          3 Leads ( R, L, F or RA, LA, LL) 

Lead selection                     I, II, III,

Wavef orm                          1 ch

Gain                               2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV, auto


HR and Alarm Range                 Adult    15 ~ 300 bpm

                                          Neo/Ped    15 ~ 350 bpm

Accuracy                           ±1% or±1bpm, which is greater

Resolution                         1 bpm 

Sensitivity                        > 200 (uVp-p) 

Differential Input Impedance       > 5 MΩ


CMRR                         Monitor > 105 dB 

                                   Operation > 105 dB 

                                   Diagnosis > 85 dB

Electrode offset potential         ±300mV 

Leakage Current                    < 10 uA

Baseline Recovery                  < 3 S After Defi. 

ECG Signal Range                   ±8 m V ( Vp-p ) 


Bandwidth                              Surgery    1 ~ 20 Hz

                                               Monitor     0.5 ~ 40 Hz

                                               Diagnostic  0.05 ~ 130 Hz

Calibration Signal                  1 (mVp-p),  Accuracy:5%

ST Segment Monitoring Range         Measure and Alarm -2.0 ~ +2.0 mV


ARR Detecting                       Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2,BRADY, MISSED BEATS,

                                               PNP, PNC,Alarm Available,Review Available


Respiration

Method                            Impedance between R-F(RA-LL)

Differential Input Impedance       > 2.5 MΩ

Measuring Impedance Range          0.3~3 Ω

Base line Impedance Range          200~4 KΩ

Bandwidth                                      0.1~2.5Hz

Resp. Rate                                  Measuring and Alarm Range

                                                    Adult 0 ~ 120 Brpm 

                                                    Neo/Ped 0 ~ 150 Brpm 

                                                   Resolution 1 Brpm 

                                                   Accuracy ±2 Brpm


Apnea Alarm                             10 ~ 40 S


NIBP 


Method                            Oscillometric

Mode                              Manual, Auto, STAT                        

Measuring Interval in AUTO Mode   1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min)

Measuring Period in STAT Mode     5 Min

Pulse Rate Range           40 ~ 240 bpm

Alarm Type                  SYS, DIA, MEAN


Measuring and alarm range        Adult Mode

                                    SYS 40 ~ 270 mmHg 

                                    DIA 10 ~ 215 mmHg 

                                    MEAN 20 ~ 235 mmHg

                                Pediatric Mode

                                    SYS 40 ~ 200 mmHg 

                                    DIA 10 ~ 150 mmHg 

                                    MEAN 20 ~ 165 mmHg

                                Neonatal Mode

                                    SYS 40 ~ 135 mmHg 

                                    DIA 10 ~ 100 mmHg 

                                    MEAN 20 ~ 110 mmHg

Resolution                      1mmHg


Accuracy                        Maximum Mean error ±5mmHg

                                Maximum Standard deviation ±8mmHg

Overpressure Protection          Adult Mode 297±3 mmHg 

                                 Pediatric Mode 240±3 mmHg 

                                 Neonatal Mode 147±3 mmHg


SpO2

Measuring Range                  0 ~ 100 % 

Alarm Range                      0 ~ 100 % 

Resolution                       1 %

Accuracy                         70% ~ 100%  2 %

                                 0%  ~  69% unspecified

Actualization intervalabout      1 Sec. 

Alarm Delay                      10 Sec.

Pulse Rate                       Measuring and Alarm Range 20~300 bpm

                                 Resolution       1bpm

                                 Accuracy ±3bpm

                                   

TEMP


Channe                          2

Measuring and Alarm Range 0 ~ 50 ℃

Resolution                      0.1 ℃

Accuracy                 ±0.2 ℃

Actualization intervalabout     1 Sec.

Average Time Constant           < 10 Sec.


IBP


Label                           ART, PA, CVP, RAP, LAP, ICP, P1, P2

Measuring and alarm range       ART 0 ~ 300 mmHg 

                                PA -6 ~ 120 mmHg

                                CVP/RAP/LAP/ICP-10 ~ 40 mmHg

                                P1 / P2-10 ~ 300 mmHg 


Press Sensor                    Sensitivity 5  uV/V/mmHg

                                         Impedance 300-3000Ω


Resolution                      1 mmHg

Accuracy                        ±2% or 1mmHg which is greater

Actualization interval         about 1 secretary


Standard:  ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature

Optional:  Nellcor SpO2, EtCO 2, IBP, Thermal Recorder