15" color TFT screen Multi-channel display Big font interface ME9000D

Share
documents & resoures

15" color TFT screen Multi-channel display Big font interface ME9000D


15" color TFT screen Multi-channel display Big font interface

ST and arrhythmia analysis

Drug dose calculation and titration table

OxyCRG dynamic view display

Respiration monitoring with apnea alarms

 

Alarm review, arrhythmia review

Patient info. Input

Anti-defibrillation design

NIBP over pressure protection

Plug-in rechargeable battery, AC/DC available. Supporting wire or wireless network.


ECG

Lead mode               5 Leads, I, II, III, AVR, AVL, AVF, V

Gain                   ×2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV,auto

Heart rate             Measure range:

                        Adult    15 ~ 300 bpm

                        Neonatal/Pediatric 15 ~ 350 bpm


Accuracy                ±1% 

Resolution              1 bpm 

Sensitivity             > 200 VμP-P 

Differential Input Impedance      > 5 M ohm


CMRR                        Monitor Mode   >100 dB 

                               Surgery Mode >100 dB 

                               Diagnostic Mode  >90 dB

Electrode offset potential     ±300mV 

Leakage Current                < 10 μA

PACE pulse detect              range±2~±700mV

                               width 0.1~2ms

                               rise time 10~100 μs

PACE pulse rejection           range ±2 ~±700mV

                               width 0.1~2ms

                               rise time 10 ~100 μs 

Baseline Recovery              < 3 s  After defibrillation. 

Signal Range                   ±8 mV p-p

Bandwidth        Surgery      1 ~ 20 Hz 

                               Monitor 0.5 ~ 40 Hz 

                               Diagnostic   0.05 ~ 130 Hz

Calibration Signal             1 mV p-p, 5% accuracy

ST measurement                 Range -2.0 ~+2.0 mV 

                               Accuracy-0.8mV~+0.8mV

                               ±0.02mV or±10%, which is greater

                               Other range: unspecified

Respiration

Method                         Impedance between RA-LL

Differential Input Impedance   >2.5 MΩ

Respiration Impedance Range     0.3~3Ω

Base Impedance Range           200Ω~4000Ω

Bandwidth                     0.1 ~ 2.5 Hz

Gain                          ×0.25,×0.500,×1,×2,×4

Respiration Rate               Measurement Range

                               Adult 0 ~ 120 BrPM

                               Neonatal / Pediatric 0 ~ 150 BrPM 

Resolution                     1 BrPM


Accuracy                0~6 BrPM: unspecified

                       7~150 BrPM:±2 BrPM or±2%

                       use the greater

Inspiriting current        < 300     A RMS max

Apnea Alarm                10 ~ 40 s



NIBP

Method                            Oscillometry 

Measure mode                      Manual, Auto, Continual

Measure Interval in AUTO Mode     1,2,3,4,5,10,15,30,60,90,120,180,240,480 min

Measure Period in Continual Mode    5 min

Pulse Rate Range               40 ~ 240 bpm

Measure and Alarm Range        Adult Mode

                                 SYS 40 ~ 270 mmHg 

                                 DIA 10 ~ 215 mmHg 

                                 MEAN20 ~ 235 mmHg

                               Pediatric Mode

                                 SYS 40 ~ 220 mmHg  

                                 DIA 10 ~ 150 mmHg 

                                 MEAN20 ~ 165 mmHg

                               Neonatal Mode

                                 SYS 40 ~ 135 mmHg 

                                 DIA 10 ~ 100 mmHg 

                                 MEAN 20 ~ 110 mmHg

Static pressure accuracy       ±3mmHg

Resolution                     1mmHg

Accuracy                       Maximum Mean error  ±5mmHg

                               Maximum Standard deviation     8mmHg

Overpressure Protection        Adult 297±3 mmHg 

                               Pediatric 240±3 mmHg 

                               Neonatal 147±3 mmHg


SpO2

Measurement Range              0 ~ 100 %

Resolution                     1 %

Accuracy                      70% ~ 100% ±2 %

                                     69%

                                     0% ~ 39%  unspecified


Pulse Rate                    Measure and Alarm Range 20~300bpm

                                     Resolution 1bpm

                                     Accuracy ±3bpm


TEMP

Channel                       2

Measure and Alarm Range       0 ~ 50℃

Resolution                             0.1℃

Accuracy(no sensor)             ±0.1(25℃-45℃),0.2±℃(other)

Accuracy(include sensor)      ±0.2℃(32℃-42℃)

                      ±0.3(other)



Standard:  ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature

Optional:  EtCO2, IBP, Thermal Recorder